Fume extraction
Fume extraction for laser cleaning
A laser does not make rust and paint disappear. It turns them into fume and fine dust, at the operator’s breathing height. Extraction is part of every laser cleaning set-up, not an extra, and it comes with duties of its own. This guide covers what is in the fume, what an extractor for this work must do, and what the law expects.
What is in the fume
The fume is whatever was on the metal, broken down. The same machine on the same steel gives off very different fume depending on the coating, which is why the coating is identified before it is touched.
- The coating itself
- Paint, primer, oil and grease break down into fine particles and gases. Their make-up depends on what the coating was.
- Metal from the coating
- Old paint can hold lead; some primers hold chromate; galvanising gives off zinc oxide; some plating holds cadmium. Each is hazardous in its own right.
- Oxide from the surface
- Rust and scale come off as fine metal oxide dust, small enough to stay in the air and reach the lungs.
- Hot particles
- Some of what comes off is still glowing as it leaves the surface, which matters for what it is drawn into.
What the extractor must do
A general workshop dust extractor is not built for this. An extractor for laser cleaning is matched to the machine, the length of hose and the coatings it will meet, and its supplier should state that in writing.
- Capture at the head
- A nozzle held close to where the beam meets the surface, or fixed to the cleaning head, so the fume is drawn in as it is made rather than after it spreads.
- Spark protection
- A spark arrestor or pre-separator ahead of the filters, so hot particles cannot reach and ignite the dust collected in them.
- Filtration for the hazard
- A particle filter fine enough for metal fume, commonly a HEPA grade, with an activated carbon stage where the coating gives off gases or odour.
- Somewhere safe for the air to go
- Filtered air returned to the workshop only where the risk assessment allows it for that coating; otherwise ducted outside.
- A way to see it is working
- An airflow indicator or alarm, so a blocked filter or a kinked hose is noticed before the fume escapes.
What the law expects
Fume from laser cleaning comes under the Control of Substances Hazardous to Health Regulations (COSHH), and work on lead paint under the Control of Lead at Work Regulations as well. In practice that means:
- Assess before starting
- COSHH requires an assessment of the substances the work will release. Know what the coating is before it is disturbed, and test it if in doubt.
- Control at source first
- Extraction at the head is the main control. Respiratory protection is added where the assessment says extraction alone is not enough, never used instead of it.
- Examine and test the extraction
- Local exhaust ventilation must have a thorough examination and test at least every 14 months, by a competent person, with the records kept for at least five years.
- Check it day to day
- Look at the hose, the nozzle position and the airflow indicator before each use, and change filters when the supplier’s instructions say.
- Handle used filters as waste
- Filters that have caught lead, chromate or other hazardous dust are hazardous waste. Change them with the right protection and dispose of them through a licensed route.
Extraction is one of the controls for Class 4 laser work; the laser safety guide covers the rest, from the controlled area to eyewear. The price guide lists extraction among what a quote should include.
Questions businesses ask
- Does laser cleaning need fume extraction?
- Yes, on every job. Whatever the laser removes goes into the air as fume and dust, and its make-up depends on the coating. Extraction at the head is the standard control, and a supplier quoting for a machine should quote the extraction with it.
- Can the extractor return filtered air to the workshop?
- Sometimes. It depends on the coating, the filtration and the risk assessment. For hazardous coatings such as lead paint or chromate primer, many businesses duct the air outside, and the assessment should say which is acceptable for the work.
- How often must fume extraction be tested?
- Under COSHH, local exhaust ventilation needs a thorough examination and test at least every 14 months, by a competent person, with the records kept for at least five years. Day-to-day checks before use are separate from that.
- Is a mask enough without extraction?
- No. Respiratory protection is the last line, added where extraction alone does not control the exposure. It protects only the wearer, it has to be face-fit tested for tight-fitting masks, and the fume still reaches everyone else nearby.